Products & Solutions / Air Treatment / Filters / Filters
Filters
Your compressed air system, production process and end product: three crucial elements your business depends on. While superb quality air is an essential ingredient for the success of your plant, untreated air may cause extensive damage and lead to serious performance degradation. To protect your investment, equipment and processes, Atlas Copco presents a full line-up of innovative filtration solutions to suit the high quality requirements of your specific application.
Reliable Quality Air

During the compressed air process, the concentration of dirt particles, oil carryover and moisture increases. This creates an abrasive mixture that, when left as such, may bring about severe instrument failures and even contaminate your end product. Atlas Copco has developed a complete rang of top-of-the-line DD, DDp, PD, PDp and QD filters which efficiently reduce all types of contamination with miniman pressure drop.
Reduced Energy Costs

Designed for maximum contaminant removel, Atlas Copco's filter range offers significant energy savings thanks to their:
-
Optimal air flow path with low resistance
- Housing and cartridge engineered for minimal pressure drop
Proven Piece of Mind

Building on many years of experience in compressed air solutions and continuous in-depth research and development, Atlas Copco offers the widest selection of filtration solutions and application knowledge. With the protection of your compressed air investment in mind, Atlas Copco has designed its filter range to meet your current and future needs while providing the superb quality air according to the latest international standards.
Compressed air purity
| Grade | Particles (micron) | Oil (ppm) |
|---|---|---|
| DD | 1 | 1 |
| PD | 0.01 | 0.01 |
| QD | - | 0.003 |
| DDp | 1 | - |
| PDp | 0.01 | - |
Technical specifications
| Filter size | Nominal capacity (1) | Max. capacity (1) | Connections G or NPT | Dimensions | Free space for cartridge replacement (2) | Weight | |||
|---|---|---|---|---|---|---|---|---|---|
| DD, DDp, PD, PDp, QD | l/s | cfm | l/s | cfm | W (mm) | H (mm) | mm | kg | |
| 9 | 9 | 19 | 11 | 23 | 3/8 | 90 | 268 | 75 | 1 |
| 17 | 17 | 36 | 21 | 45 | 1/2 | 90 | 268 | 75 | 1.1 |
| 32 | 32 | 68 | 40 | 85 | 1/2 | 90 | 323 | 75 | 1.3 |
| 44 | 44 | 93 | 55 | 117 | 3/4 & 1 | 110 | 374 | 75 | 1.9 |
| 60 | 60 | 127 | 75 | 159 | 1 | 110 | 414 | 75 | 2.1 |
| 120 | 120 | 254 | 150 | 318 | 1-1/2 | 140 | 520 | 100 | 4.2 |
| 150 | 150 | 318 | 188 | 399 | 1-1/2 | 140 | 603 | 100 | 4.5 |
| 175 | 175 | 371 | 219 | 464 | 1-1/2 | 140 | 603 | 100 | 4.6 |
| 280 | 280 | 594 | 350 | 742 | 2 & 2-1/2 | 179 | 689 | 150 | 6.9 |
| 390 | 390 | 827 | 488 | 1035 | 3 | 210 | 791 | 200 | 11 |
| 520 | 520 | 1102 | 650 | 1378 | 3 | 210 | 961 | 200 | 12.6 |
| 520F | 520 | 1102 | 650 | 1378 | DN80 | 330 | 1292 | 728 | 71 |
| 780F | 780 | 1645 | 975 | 2067 | DN100 | 460 | 1320 | 686 | 127 |
| 1050F | 1050 | 2226 | 1313 | 2784 | DN100 | 460 | 1320 | 686 | 128 |
| 1400F | 1400 | 2968 | 1750 | 3710 | DN150 | 550 | 1464 | 672 | 189 |
| 1800F | 1800 | 3816 | 2250 | 4770 | DN150 | 570 | 1467 | 681 | 210 |
| 2100F | 2100 | 4452 | 2625 | 5565 | DN150 | 620 | 1499 | 676 | 251 |
| 2700F | 2700 | 5724 | 3375 | 7155 | DN200 | 740 | 1634 | 692 | 328 |
| 3150F | 3150 | 6678 | 3938 | 8349 | DN200 | 740 | 1634 | 692 | 329 |
| 4800F | 4800 | 10176 | 6000 | 12720 | DN250 | 740 | 1662 | 800 | 507 |
| 7200F | 7200 | 15256 | 9000 | 19080 | DN300 | 1000 | 1755 | 850 | 675 |
(1) Nominal pressure: 7 bar(e)/102 psig; temperature: 20°C
(2) Distance from the center of the flange down to the lowest point of the vessel.
- Leaflet Compressed Air Filters (5355 kB, Pdf document) - Download