Products & Solutions / Working, Control and Instrument Air / Oil-injected Screw Compressors MAS GA 110-160 / Oil-injected screw compressors MAS GA 110-160
Oil-injected screw compressors MAS GA 110-160
Your benefits

MAS GA 160
Optimized energy
- Always latest energy-saving screw design
- Several starter types: Star/Delta, Dol and Soft Starter, VSD and diesel driven on request
- FAD mentioned is including oil separator, aftercooler and water separator
Flexible installation and operation
- Flanged air and water connection, on the same side of the unit for easy installation
- Marine motor with reduced starting current, avoiding stress on generator system
- Elektronikon® (MKIV) regulation, ensuring reliable and safe operation
- Control panel (MKIV) including hour counter, amp meter, high-temperature outlet, motor overload, low cooling water, motor heating on (lamp), auto operation sign and general alarm
- 50 Hz units available as an option
Economical space usage
- Small footprint (LxWxH): 3000 x 799 x 1850 mm
- Mounted on oil-containing frame, fully interconnected, no extra pipework, no coaming needed around compressor, can be fitted straight on frames or
floorplate, bolted or welded. - Including oil and aftercooler, water separator, air inlet filter
- Without canopy, reducing equipment volume, easy access and only one side access possible.
Ease of operation
- Voltage free contacts to customer installation (open-closed): automatic operation, general warning, general
shut-down, load-unload, motor running and local-remote - Analog signals to customer installation (4-20 mA): all signals can be provided such as outlet pressure and motor current,
temperature, etc.
Technical Specifications
Open table| Drive | Direct driven working air compressor |
|---|---|
| Outlet air temperature | cwt+5°C |
| Cooling | Water-cooled (sea and fresh water) |
| Inlet temperature cw | 36°C |
| Ambient temperature | 45°C |
| Max. pressure | 14 bar |
| Size (L x W x H) | 3000 x 799 x 1850 mm |
| Compressor | kW | FAD*, 60 Hz (m³/h) | Cooling water capacity | Weight | |||
|---|---|---|---|---|---|---|---|
| 6 bar | 8.6 bar | 10 bar | 14 bar | l/s | kg | ||
| MAS GA 110 | 125 | 1260 | 1152 | 1036 | 868 | 3 | 1938 |
| MAS GA 132 | 150 | 1465 | 1354 | 1242 | 1051 | 3 | 2073 |
| MAS GA 160 | 185 | 1742 | 1541 | 1498 | 1292 | 4 | 2103 |
* FAD is according to ISO 1217
cwt = cooling water temperature
50 Hz available on request