The Atlas Copco QAS 70 ID T4F generators are prime power, multi-voltage, sound attenuated, mobile generators. They are powered by an Isuzu Tier 4 Final, liquid-cooled, four cylinder diesel engine.
The units consist of an alternator, diesel engine, cooling system, electrical distribution and control systems - all enclosed within a sound attenuated enclosure fabricated from powder coated galvannealed steel. A broad range of undercarriage formats and options are available. Special attention has been given to the overall product quality, user friendliness, ease of serviceability, and economical operation to ensure best in class total cost of ownership.
Performance | Units | QAS 70 ID |
Frequency | Hz | 60 |
Rated prime power 3ø | kW/kVA | 56 / 70 |
Rated standby power 3ø | kW/kVA | 60 / 75 |
3ø Power factor | 0.8 | |
3ø Voltage in 480V switch position (series Star w/ Neutral) | V | 480Y / 277 |
Amp capacity @480V | A | 84 |
3ø Voltage in 240-208V switch position (Parappel Star w/ Neutral) | V | 240YY / 139-208YY |
Amp capacity @ 240V | A | 168 |
Amp capacity @208V | A | 168 |
Rated prime power 1ø | kW/kVA | 39/39 |
1ø Power factor | 1 .0 | |
1ø Voltage in 120-240V switch position (Zig-Zag) | V | 240 / 120 |
Amp Capacity @240V | A | 162.5 |
Amp Capacity @120V | A | 200 |
Alternator (4 Pole, 12 Wire) | Leroy Somer | LSA 42.3 I9 |
Excitation system | AREP (auxiliary winding) | |
Digital Automatic Voltage Regulator (+/- 0.25%) |
Leroy Somer | R438 |
Insulation | Class H | |
Main Breaker - Shunt Trip | A | 400 |
Power Distribution - Terminal Board | 5 Wire (L1, L2, L3, N, Ground) | |
Terminal Board Connections | Bare Wire Terminals | |
Maximum Terminal Cable Size | 350MCM | |
Convenience Receptacles | 2 x NEMA 5-20R & 2 x 125/250V 50A CS6364 |
Engine | Units | QAS 70 ID |
Model | Isuzu | 4JJ1X |
US EPA Family | HSZXL03.0RXB |
|
US EPA Tier | Tier 4 Final | |
Displacement | L | 2.99 |
Cylinders | # | 4 |
Continuous Engine Power Output | HP (kW) | 88 (65.5) |
Gross engine power output | HP (kW) | 95 (71) |
Rated Speed | RPM | 1800 |
Engine control | ECU | |
Aspiration | Turbo w/Intercooler | |
Engine oil capacity | US gal (L) | 3.7 (14) |
Engine coolant capacity | US gal (L) | 1.6 (6) |
Max. ambient temperature (@Sea Level) | °F (°C) |
122 (50) |
Min. starting temperature (Without coolant heater on) | °F (°C) |
14 (-10) |
Min. starting temperature (With coolant heater on) | °F (°C) |
TBA |
Electrical system (Negative ground) | V | 12 |
Engine alternator output | A | 110 |
Battery Capacity (Cold Cranking Amps) | A | 725 |
Sound Pressure Level @ 23’(7 m) @ 75% Load | dB(A) | 67.1 |
Fuel and DEF Systems | Units | QAS 70 ID |
Capacity of fuel tank |
US Gal | 110 |
Fuel Consumption at 0% load |
Gal/hr (L/hr) | 0.28 (1.27) |
Fuel Consumption at 50% load |
Gal/hr (L/hr) | 2.54 (9.61) |
Fuel Consumption at full load (100%) |
Gal/hr (L/hr) | 3.95 (14.95) |
Fuel Type |
Ultra-Low Sulfur Diesel ONLY |
|
DEF Ratio |
% |
3.1 |
Fuel Autonomy |
Hours | 27.8 |
Capacity of DEF tank |
US Gal |
7.1 |
During the mining process, machines such as excavators, drillers, cranes, and conveyor belts use a lot of electricity. No matter what type of mining is taking place, Atlas Copco's QAS 70 diesel generator is the best choice as it is portable and can be utilized in remote and extreme mining zones.
Outdoor events with big tents, lighting and all sorts of machinery running from vendors will require power from a mobile generator. Atlas Copco’s QAS 25, 45 or 70 diesel generators are a great fit for events as they are silent, compact and towable. There are also convenience receptacles as standard to use in single phase 120V outlets, California style 240V outlets, or Camlocks as an option.