The cost of air generation and how to calculate it
Compressed air is widely considered the fourth utility, in addition to electricity, water, and gas. That versatility comes at a cost: it is much more expensive to generate in comparison.
It is estimated that 10% of all energy used by the industrial sector goes into compressed air, and about 80% of what air generation costs is spent on energy. That is far more than the investment in compressors or their upkeep. This guide breaks that cost down and shows you how to work out your own.
How to calculate your compressed air cost
You need the total package power consumption, running hours, how the machine is loaded, and your local electricity price.
Yearly energy cost (in your local currency) = total package power consumption (kW) × running hours × your local electricity price per kWh × share of time at this load × share of total package power
Run it once for each load state and add the results.
An illustrative example
The figures below are fictional and only show how the calculation works.
A compressor with a total package power of 160 kW / 215 hp runs 6,800 hours a year, loaded 85% of the time and unloaded the rest at 25% power. That is about 966,000 kWh a year. Multiply that by your local electricity price per kWh to get your yearly energy cost.
Your cost per unit of air
Divide your yearly energy cost by the air you deliver in the same period, in cubic metres (m³) or cubic feet (ft³). The result depends on your compressor, your pressure, and your local electricity price.
Understanding the cost of compressed air and how to keep it low
Very little of that cost sits in the compressor alone. Click through the compressor room below to see the eight places where a system gains or loses efficiency.
A comprehensive look at your compressed air system
A compressor on its own is rarely enough. Most applications need a complete system that delivers high-quality air exactly where it is used. That is also where the savings are: once you understand your air needs, you can look at each component in the network and what it costs to run.
It also helps to plan for the system you expect to have, not only the one you have today. If you are about to scale up production or add a new process, sizing for that future demand now is usually cheaper than adapting the system later.
Every component of a compressed air system
1. Air compressors
First, there is the compressor itself, whose initial price tag accounts for only a fraction of its total cost of ownership. Because energy costs make up the bulk of the overall cost, it makes no sense to buy a less efficient machine that uses a lot of energy.
When selecting the right compressor, air demand matters. If the air supply is stable, a fixed-speed compressor may be the best solution. If demand fluctuates, a model with a variable speed drive (VSD) will likely be ideal. Larger facilities often call for multiple compressors, switched on and off depending on demand.
2. Dryers and filters
For some applications, air quality hardly matters. For many others, it is essential: it keeps contaminants out of the end product, especially in food and pharmaceuticals, and protects downstream equipment from corrosion.
This is the hidden cost of low-quality air. Skipping dryers and filters is cheaper in the short run but costs more later. Choose the right technology for the application, which limits pressure drop. Each extra 1 bar / 14.5 psi generated to push air through a clogged filter adds about 7% to the energy bill. As with compressors, energy is the main contributor to the cost of owning a dryer.
3. Drains
Intelligent zero-loss drains discharge condensate only when needed. This saves energy, unlike timer drains, which open at a set interval even when there is no condensate to remove and vent air you paid to make on every cycle.
4. Piping
Even the most efficient compressor wastes energy if the piping is leaky or the wrong size. Adequate piping removes air restrictions and pressure drop, and reduces air leakage. Where pressure drop is met by raising the set pressure instead, each extra 1 bar / 14.5 psi costs about 7% more energy.
As well as picking the proper material, operators choose between a loop and a branch system. A loop can deliver air from several directions. A branch flows one way, feeding the closest application first, and can cause a pressure drop downstream that affects production.
5. Air receiver tanks
Receiver tanks store the compressed air and act as a buffer between what the compressors supply and what production uses. Properly sized, a receiver removes false demand, the short, sharp peaks that look to the controls like a real shortfall, so no extra compressor has to start, and system pressure changes less.
That steadier pressure also means compressors switch between load and unload less often, which cuts wasted running time. Pressure controls stabilise the pressure in the air net, which reduces leakage and saves energy. A receiver that is too small cannot do this, so check its size whenever your air demand changes.
6. Ventilation and energy recovery
Many companies research the compressed air system they invest in carefully, but overlook the heat it produces. Compressing air generates a lot of waste heat, and if that heat stays in the compressor room, the equipment has to work harder. Good ventilation carries it away, which lowers energy consumption.
Most of that heat can be recovered and used elsewhere, for example, to heat rooms, water, or processes. Good ventilation stops energy from being wasted, while energy recovery turns waste heat into a saving. Both depend on how the compressor room is laid out, so consult experts before you design it.
7. Air leakage
Many inefficiencies can be removed before a system begins operation, but it also needs monitoring while in use. That includes the detection and repair of expensive air leaks. A single 3 mm / 0.12 in hole at 7 bar / 102 psi leaks around 11 l/s / 23 cfm. That wastes roughly 35,000 kWh a year, and unlike production, it does not stop at the end of a shift.
Simply increasing the system pressure increases leakage without addressing it, and only increases energy use. Instead, find the leaks with an ultrasonic detector during a shutdown, fix the biggest first, and repeat on a schedule.
8. Central controller
In systems with more than one compressor, a central controller controls capacity, regulates speed, and reduces the average pressure band the whole system runs at.
That last point is where the money is: a pressure reduction of 1 bar / 14.5 psi lowers energy usage by 7%. A properly designed and maintained system can dramatically reduce operating costs, so planning pays off later.
Where the biggest savings come from
Applied to the example above, these rank as follows.
| Measure | What it does | Worth in the example | Cost |
|---|---|---|---|
| Fix leaks instead of raising pressure | Removes a load running day and night | About 27,000 kWh a year per 3 mm / 0.12 in leak | Survey plus labour |
| Reduce average pressure by 1 bar / 14.5 psi | About 7% less energy | About 68,000 kWh a year | Nothing, if there is headroom |
| Match the compressor to demand | Removes unloaded running | Depends on load pattern | Capital, at replacement |
| Recover the waste heat | Offsets heating spend | Depends on heat demand | Capital, best at design |
| Sequence compressors centrally | Narrows the pressure band | In the 1 bar / 14.5 psi figure | A controller |
The first two measures usually require little investment, which makes them a good place to start. The others are best considered when a compressor is due for replacement, since the choice you make then shapes its efficiency for many years to come.
Find out what your compressed air really costs
Every figure here is an example until it is measured on your own system. Our specialists will assess your compressor room and show you what your air really costs.
Frequently asked questions
How do I work out the cost of compressed air?
Multiply the total package power consumption (kW) by the running hours, your local electricity price per kWh, the share of time at that load, and the share of total package power.
Why is compressed air so expensive?
Because generating it takes a lot of energy. Energy is about 80% of the cost of air generation, far more than the compressor or its upkeep.
How much does an air leak cost?
A single 3 mm / 0.12 in leak at 7 bar / 102 psi wastes around 11 l/s / 23 cfm, roughly 35,000 kWh a year if the system runs all year. Multiply by your local electricity price to see what it costs in your local currency.
How much can I save by lowering system pressure?
About 7% of energy use for every 1 bar / 14.5 psi reduction. First, check that production genuinely needs the current setting: pressure is often raised to make up for leaks, and repairing the leaks saves more than lowering the pressure alone.