If you need to reduce production and switch off your air compressors temporarily, we have put together some stopping and re-starting guidelines for you to follow.
If the compressors are to be stopped for a prolonged period of time the following rules should be applied.
First turn off the power supply to the air compressor, remove the drive shaft protection guard and turn the drive coupling to check that the compressor is free to turn. If the compressor turns freely, re fit the guard and turn on the power supply to the compressor; turn on the cooling water and air blast cooling system if the compressor is water cooled. Close the compressor air discharge valve and start the compressor, then slowly open the air discharge valve until the air pressure equalises out between the compressor and the air net, then the compressor is back online. If the air compressor is connected to a sequence controller, make sure the compressors are integrated onto the controller/ optimiser.
If you require any further information, our contact details are: (01) 450 5978 / info.ireland@ie.atlascopco.com.
Check the safety information related to working with chemical products