Performance | Units | QAS 25 JD |
Frequency | Hz | 60 |
Rated prime power @480V 3ø | kW/kVA | 20/25 |
Rated standby power @480V 3ø | kW/kVA | 22/28 |
3ø Power factor | 0.8 | |
3ø Voltage in 480V switch position (Series Star w/ Neutral) | V | 480Y / 277 |
Amp capacity @480V | A | 30 |
3ø Voltage in 240-208V switch position (Parallel Star w/ Neutral) | V | 240YY / 139-208YY |
Rated Prime Power @240V 3Ø |
A | 20/25 |
Amp capacity @240V | A | 60 |
Rated Prime Power @ 2080V 3Ø |
kW/kVA | 18/23 |
Amp capacity @208V | A | 63 |
Rated prime power @240V 1ø | kW/kVA | 13/13 |
1ø Power factor | 1 .0 | |
1ø Voltage in 120-240V switch position (Zig-Zag) | V | 240 / 120 |
Amp Capacity @240V | A | 54 |
Amp Capacity @120V | A | 54 x 2 |
Alternator (4 Pole, 12 Wire) | Leroy Somer | LSA 40 M5 |
Excitation system | AREP (auxiliary winding) | |
Digital Automatic Voltage Regulator (+/- 0.25%) |
Leroy Somer | D350 |
Insulation | Class H | |
Main Breaker - Shunt Trip | A | 63 |
Power Distribution – Terminal Board | 5 Wire (L1, L2, L3, N, Ground) | |
Terminal Board Connections | Bare Wire Terminals | |
Maximum Terminal Cable Size | 350MCM | |
Convenience Receptacles | 2 x NEMA 5-20R & 2 x 125/250V 50A CS6364 |
The WEDA D10N drainage pump features a max head of up to 52ft, max flow of 119USgpm, and can withstand solids of up to 0.16in.
The WEDA drainage pumps handle either clean or sand-laden water, even with small solid particles, with the best performance and efficiency. These pumps are particularly suitable for general dewatering applications, ground water, raw water, construction sites and harsh conditions on site.
Product Code | WEDA D10N |
Installation | Portable drainage pump |
Hydraulic range | N - normal head |
Insulation class | F (+155°C/+311°F) IEC 85 |
Protection class | IP68 |
Voltage variation | Max ± 5% of nominal voltage |
Voltage imbalance | Max 2% - between phases |
Max start-stop | Max 30 starts/hour |
Cable | H07RN-F (20 m) or SOOW AWG (65 ft) |
Casted parts | Corrosion resistant aluminum |
Impeller | High chrome iron, 55±5 HRC |
Wear parts | Rubber (NBR) |
Strainer | Hard sole - reinforced polyethylene |
Shaft | Stainless steel |
O-rings | Rubber (NBR) |
Main bearing | Single row ball bearing in oil |
Mechanical seal | Primary + secondary: grease lubricated lip seal on WC wear sleeve |
Built-in controls and protection | 1 ph: capacitor + contactor 3 ph: contactor + control relay |
Thermal contacts | 140°C / 284°F |
Options / accessories | Float switch Zinc anodes Epoxy coating Low suction collar Quick couplings (hose / NPT / ISO-G / Camlock / Storz) Pump raft Terminal board NSSHÖU screened cable |
Solids handling, strainer hole | 0.16 in |
Liquid temperature | Max 104°F |
Depth of immersion | Max 65 ft |
Max liquid specific gravity | 1.1 |
pH of the pumped liquid | pH 5–8 |
Weight and dimensions | N - Normal Head |
Discharge connection (in) | 2 |
Hieght (in) | 15.5 / 18.5 (115V) |
Width (in) | 8.8 |
Diameter (in) | 7.3 |
Diameter (in) | 28 |
Rating | 1 ph | 3 ph | Standard Cable |
Power P1 | 1.6 kW | 1.2 kW | |
Power P2 | 1.5 HP | 1.5 HP | |
Shaft speed | 3500 r.p.m. | 3500 r.p.m. | |
115 V | 16.2 A | - | AWG14 |
230 V | 8.1 A | 4.6 A | AWG16 |
460 V | - | 2.3 A | AWG16 |
575 V | - | 1.8 A | AWG16 |
WEDA D10N Drainage Pump is used for various general dewatering purposes on construction sites. During construction, it is crucial to remove shallow water and groundwater to keep the project on schedule. Overall, the Atlas Copco D04N Pump is portable and easy to move from site to site.
Quarries require dewatering for a variety of reasons. In order to mine the aggregate for concrete and other construction materials, it needs to be sufficiently dry at the quarry. The D10N Pump can provide the dry sump needed for proper working conditions.