Performance  Units QAS 25 JD 
Frequency  Hz  60 
Rated prime power @480V 3ø  kW/kVA  20/25 
Rated standby power @480V 3ø  kW/kVA  22/28
3ø Power factor    0.8 
3ø Voltage in 480V switch position (Series Star w/ Neutral)star w/neutral)  480Y / 277 
Amp capacity @480V  30 
3ø Voltage in 240-208V switch position (Parallel Star w/ Neutral)arallel star w/neutral)  240YY / 139-208YY 

Rated Prime Power @240V 3Ø

20/25

Amp capacity @240V  60 

Rated Prime Power @ 2080V 3Ø

kW/kVA

18/23

Amp capacity @208V  63 
Rated prime power @240V 1ø  kW/kVA  13/13 
1ø Power factor    1 .0
1ø Voltage in 120-240V switch position (Zig-Zag)g-Zag)  240 / 120 
Amp Capacity @240V  54 
Amp Capacity @120V  54 x 2 
Alternator (4 Pole, 12 Wire) Leroy Somer LSA 40 M5
Excitation system   AREP (auxiliary winding)

Digital Automatic Voltage Regulator (+/- 0.25%)

Leroy Somer D350
Insulation   Class H
Main Breaker - Shunt Trip A 63
Power Distribution – Terminal Board   5 Wire (L1, L2, L3, N, Ground)
Terminal Board Connections   Bare Wire Terminals
Maximum Terminal Cable Size   350MCM
Convenience Receptacles   2 x NEMA 5-20R & 2 x 125/250V 50A CS6364

The WEDA D10N drainage pump features a max head of up to 52ft, max flow of 119USgpm, and can withstand solids of up to 0.16in.

 

The WEDA drainage pumps handle either clean or sand-laden water, even with small solid particles, with the best performance and efficiency. These pumps are particularly suitable for general dewatering applications, ground water, raw water, construction sites and harsh conditions on site.

 

View and/or Download WEDA D10N: Brochure / Datasheet

TECHNICAL DATA

Product Code WEDA D10N
Installation  Portable drainage pump
Hydraulic range N - normal head
Insulation class F (+155°C/+311°F) IEC 85
Protection class  IP68
Voltage variation  Max ± 5% of nominal voltage
Voltage imbalance Max 2% - between phases
Max start-stop Max 30 starts/hour
Cable H07RN-F (20 m) or SOOW AWG (65 ft)
Casted parts Corrosion resistant aluminum
Impeller High chrome iron, 55±5 HRC
Wear parts Rubber (NBR)
Strainer Hard sole - reinforced polyethylene
Shaft Stainless steel
O-rings  Rubber (NBR)
Main bearing Single row ball bearing in oil
Mechanical seal Primary + secondary: grease lubricated lip seal on WC wear sleeve
Built-in controls and protection 1 ph: capacitor + contactor 3 ph: contactor + control relay
Thermal contacts 140°C / 284°F
Options / accessories

Float switch

Zinc anodes

Epoxy coating

Low suction collar

Quick couplings (hose / NPT / ISO-G / Camlock / Storz)

Pump raft

Terminal board

NSSHÖU screened cable

Solids handling, strainer hole  0.16 in
Liquid temperature Max 104°F
Depth of immersion Max 65 ft
Max liquid specific gravity 1.1
pH of the pumped liquid pH 5–8
Weight and dimensions N - Normal Head
Discharge connection (in)
Hieght (in) 15.5 / 18.5 (115V) 
Width (in) 8.8
Diameter (in) 7.3
Diameter (in) 28

PERFORMANCE CURVES

POWER RATING

 

Rating  1 ph 3 ph Standard Cable
Power P1 1.6 kW 1.2 kW  
Power P2 1.5 HP 1.5 HP  
Shaft speed  3500 r.p.m. 3500 r.p.m.  
115 V 16.2 A - AWG14
230 V  8.1 A 4.6 A AWG16
460 V - 2.3 A AWG16
575 V - 1.8 A AWG16