Close

The Atlas Copco QAS 200 JD T4F generators are prime power, multi-voltage, sound attenuated, mobile generators. They are powered by a John Deere T4 Final liquid-cooled, six-cylinder diesel engine.

The units consist of an alternator, diesel engine, cooling system, electrical distribution and control systems - all enclosed within a sound attenuated enclosure fabricated from powder coated steel with zinc rich primer. 6000 hour salt spray tested. A broad range of undercarriage formats and options are available. Special attention has been given to the overall product quality, user friendliness, ease of serviceability, and economical operation to ensure best in class total cost of ownership.

All QAS generators include the latest Tier 4 Final engine and have a footprint that is up to 20 percent smaller than the previous generation. The starting mechanism ensures that stable power is achieved in less than six seconds.

View and/or Download QAS 200 JD T4F: Datasheet / Brochure

STANDARD FEATURES

  • Compact, sound attenuated, corrosion resistant, with single point lifting and 110% fluid containment
  • Dual axle trailer as standard, available as a skid mounted unit with forklift pockets as an option
  • Heavy Duty alternator with AREP excitation and marine grade protection
  • Single side service with long run filters and 500-hour service intervals
  • Extremely reliable and durable John Deere 6068HFG05
  • Emergency Stop
  • Remote signal Start / Stop

BENEFITS

  • Extremely durable and environmentally sensitive, designed to be used for everything from the oil field to special event power
  • Versatility, giving you the flexibility to match your machine to the correct application
  • Start-up power for the most demanding sites with 300% over load starting capabilities
  • Heavy duty oil, air and fuel filters extend the maintenance interval to 500 hours for reduced total cost of ownership
  • Proven engine platform with high reliability and durability
  • External, recessed emergency stop for increased safety
  • Allows connection as a critical back-up unit via a 2-wire dry contact connection in the distribution panel

TECHNICAL DATA

Generator  Units  QAS 200 JD 
Frequency  Hz 50 60
Rated Prime Power 3Ø (600,480,240V @ 60Hz, 400V @ 50Hz)  kW/ kVA 134/168 160/200
Rated Standby Power 3Ø (600,480,240V @ 60Hz, 400V @ 50Hz)  kW/ kVA 147/185 176/220
3Ø Power Factor    0.8 0.8
3Ø Voltage @ 600V (Series Star w/Neutral)  V - 600Y/346
Amp Capacity @ 600V/60Hz  A - 192
3Ø Voltage @ 480V (Series Star w/Neutral)  V - 480Y/277
Amp Capacity @ 480V/60Hz  A - 241
3Ø Voltage @ 240-208V (Parallel Star w/ Neutral)  V - 240Y/139 - 208Y/120
Amp Capacity @ 240V/Hz  A - 481
Amp Capacity @ 208V/Hz  A - 500
Rated Prime Power 1Ø  kW/ kVA - 102/102
1Ø Power Factor    - 1.0
1Ø Voltage @ 120-240V (Zig-Zag)  V - 240/120
Amp Capacity @ 240V  A - 425
Amp Capacity @ 120V  A - 2 x 425
3Ø Voltage @ 400V (Series Star w/Neutral)  V 400Y/231 -
Amp Capacity @ 400V/50Hz  A 243 -
Performance Class (acc. ISO 8528-5:1993)    G2 G2
Single Step Load Acceptance (0-PRP) @60Hz  kW(%)  89.8 (67%) 113(70.6%)
Sound Pressure Level @ 23’(7 m) @ 75% Load2  dB(A)  69 71
Alternator (4 Pole, 12 Wire)  Leroy Somer LSA 44.3 VL 13
Excitation   AREP (auxiliary winding)
Automatic Voltage Regulator (+/- 0.5%) Leroy Somer D350
Insulation    Class H
Main Breaker - Shunt Trip  A 500
Power Distribution – Terminal Board    5 Wire (L1, L2, L3, N, Ground)
Terminal Board Connections    Bare Wire Terminals
Maximum Terminal Cable Size    350MCM
Convenience Receptacles    (2) NEMA 5-20R &
(3) 125/250V 50A CS6364
 
       

Engine  Units  QAS 200 JD 
Model  John Deere  6068HFG05 
US EPA Tier    Tier 4 Final 
Displacement  6.8 
Cylinders 
Continuous Engine Power Output  HP (kW)  235 (175) 
Gross Engine Power Output  HP (kW)  257 (192) 
Rated Speed  RPM  1800 
Engine Control    ECU 
Aspiration    Turbocharged w/ Intercooler 
Engine oil capacity4  US Gal (L)  8.6 (32.5) 
Engine coolant capacity  US Gal (L)  10.5 (39.7) 
Maximum Ambient Temperature (@ Sea Level)5  °F (°C)  122 (50) 
Min. Starting Temp (w/o heater)  °F (°C)  14 (-10) 
Minimum Starting Temperature (with heater)6  °F (°C)  -13 (-25) 
Electrical System (Negative Ground)  24 
Engine Alternator Output  60 
Battery Capacity (Cold Cranking Amps)  (2) 685 
       

Fuel System  Units  QAS 200 JD 
Fuel Consumption @ 25% load 50Hz / 60Hz  US Gal/hr (L/hr)  3.2 (12.0)  4.1 (15.4) 
Fuel Consumption @ 50% load 50Hz / 60Hz  US Gal/hr (L/hr)  5.2 (19.7)  6.4 (24.2) 
Fuel Consumption @ 75% load 50Hz / 60Hz  US Gal/hr (L/hr)  7.0 (26.5)  8.2 (31.0) 
Fuel Consumption @ 100% load 50Hz / 60Hz  US Gal/hr (L/hr)  8.8 (33.3)  10.8 (41.0) 
Fuel Type    Ultra-Low Sulfur Diesel ONLY 
Fuel Tank Capacity  US Gal (L)  290 (1068) 
Fuel Autonomy @ 75% load and 90% of tank capacity  Hr  37.3  31.7 
DEF Tank Capacity  US Gal (L)  25 (94.6) 

DEF Autonomy @ 75% load and 95% of DEF capacity

Hr 90.0 

Applications & Use Cases

Construction

Construction site with QAS 40 and XAS 97

Generators can supply power to temporary structures and construction equipment that require electricity to operate. The QAS 200 Portable Generator is suitable for less complex projects such as small road construction, single family houses, and low-rise apartments.

Events

Winter campaign light tower and portable generator top banner

Outdoor events such as festivals, sporting events, and the like depend on high-performing generators to keep the function running smoothly. Easy-to-use interface and water-resistant design ensure inclement weather or poor handling will not impede the event.

Utilities

QAS 150 ESF mobile diesel generator

Natural disasters and inclement weather are the main causes of power outages. Protect yourself against an outage with our QAS 200 Generator. With an intuitive system controller, you have advanced warning and alert parameters for added safety.

Applications & Use Cases

explainer icon